Credit: Contesta Oy Finnland – microscopic image of a concrete sample – created on a SANXO HD digital microscope
Petrographic analysis with SANXO digital microscope – Quality assessment of concrete core samples
Laboratory quality assessment inspections at Finnish engineering company CONTESTA OY show the fitness of SANXO digital microscope at petrography. The versatility of SANXO – Scope HD U10 allows inspecting the different aspects of concrete quality with one device. Changing the light source from visible light into UV lights takes little effort and it opens new perspectives to inspection.
At the visible spectrum we can analyze the raw, uncured sample. UV light is needed to inspect the sample infiltrated with epoxy and fluorescent dye.
The operator can conduct the visual inspection instantly at the workbench and it is also possible to save the magnified image to a network drive where it can be an input to an AI supported software to make calculations on the water to cement ratio of the sample or other aggregate content.
Live image visual inspection may cover the following phenomena:
- Unwanted reactions of constituting elements. Some chemical reactions result recognizable formations of minerals. They may expand during the chemical reactions and the growth of certain elements can crack the rigid surrounding cement paste.
- Volume of the air void against the complete volume
- Micro cracks
- Degree of corrosion on the surface of the steel reinforcement rods
Further possibilities of artificial intelligence backed petrographic analysis
The magnified image can saved directly to a network drive also by using SANXO – Scope HD U10’s Wi-Fi connection. The transferred images, especially the ones taken at UV light will then be the subject of quantitative image analysis. At UV light, the capillary pores and air voids appear shiny on the prepared sample, while aggregates and unhydrated cement particles remain black. The image histogram also provides a basis to determine water to cement ratio or to detect irregular fly ash content. It is possible to detect whether the capillaries are connected or segmented. Typically they are segmented if the w/cm is less than 0,45. If they are connected, that can lead to percolation, a major source of quality deterioration of the concrete structure.
reference:
- concrete sample from https://contesta.fi/ The concrete specialist company
- Ph.D., P.G.,Rothstein, D., 2008, Petrographic Investigations of Concrete Deterioration